GUFFANTI MARTÍNEZ, DIEGO ANDRES
Preferred name
GUFFANTI MARTÍNEZ, DIEGO ANDRES
Main Affiliation
GISER - Grupo de Investigación en Sistemas Embebidos y Robótica
Web Site
ORCID
0000-0002-1244-291X
Scopus Author ID
57200385407
23 results
Now showing 1 - 10 of 23
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Organic zinc sources in broiler production at high altitude under on-top supplementation or total or partial replacement: 2. Effects on tibia and blood characteristicsThe use of organic Zn sources has been claimed to reduce the environmental impact of poultry production and improve broiler performance and the quality of products. This study investigated the effects of three organic Zn supplementation strategies (i.e., TRE, total replacement; PRE, partial replacement; OTS, on-top supplementation) on tibia and blood biochemistry characteristics of broilers at high altitudes. Male Cobb 500 chicks were distributed in 54 floor pens (22 birds each) and assigned to nine experimental treatments. Birds were fed mash diets under three feeding phases until 42 days and following the standard Ecuadorian high-altitude production standard practices. The treatments were a basal diet supplemented with three inclusion rates of ZnSO4 and the same diets including or not Zn from one of two organic Zn sources (i.e., ZPR, Zn proteinate; ZAC, Zn amino acid complex). Basal diets were analyzed for Zn concentration. Tibia ash and Zn concentrations and serum biochemistry variables were determined at 21 and 42 days. The strategies to supplement organic Zn were compared with the reference treatment containing 100 ppm Zn as ZnSO4 (the standard practice; STD) using mixed models, being the block (i.e., the replication) as a random factor. The interaction of the strategy with the organic Zn source was assessed with the ANOVA and multiple comparisons. The organic Zn sources were compared considering the feed intake a random factor, and their interaction with the dietary Zn level was assessed using multiple regression. No overall effect of the Zn supplementation strategy was observed other than the reduced Zn concentration at 21 days in TRE birds. At 21 days, PRE and TRE increased the serum protein and phosphorus concentrations, respectively. At that age, TRE also increased insulin concentration, but only in the ZAC-fed birds. However, TRE produced the opposite effect on serum protein at 42 days. At the same age, ZAC-fed birds showed lower serum phosphorus concentration than ZPR-fed ones regardless of the dietary Zn supplementation level or the Zn intake. Also, ZAC under TRE produced no effect on tibia Zn concentration compared to STD, but ZPR increased it. The ZPR increased the tibia Zn concentration when fed under PRE or TRE, but not under OTS. In conclusion, the results showed no adverse effect of PRE or TRE strategies on tibia characteristics. The data indicate likely different effects of PRE and TRE on protein metabolism and a possible negative interaction of the organic Zn with a high Zn content as ZnSO4.Scopus© Citations 4 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Human Gait Analysis Using Non-invasive Methods with a ROS-Based Mobile Robotic Platform(Springer International Publishing, 2020-11-10); ;Alberto BruneteMiguel Hernando GutierrezMobile robotic platforms for human gait analysis could open the gap to multiple medical applications and new discoveries. They could take several advantages over certified photogrammetric systems by making possible gait analysis without space limitations. In this document we present the design of a new ROS-based mobile robot platform for human gait analysis. All processes are ROS-based and Nuitrack SDK is used to develop the skeleton tracking application with a depth camera. During the procedure we described the design of the control law implemented for gait analysis. We developed a lead compensator by root locus method to increase the stability and speed response of the system. The error of measurement with respect to a certified photogrammetric system was considerably low during positioning task. Additional measurements were performed to verify the acquisition of gait parameters. These included spatio-temporal variables and range of movement (ROM) of knee and hip during joint excursions. Results showed that this mobile robotic platform represents a non-invasive alternative that could be improved for use in biomechanical human gait analysis.Scopus© Citations 2 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Control Design and Validation of Gait Analysis with the Robogait Mobile Robotic Platform(Springer Nature Switzerland, 2025-09-03); ;Alberto Brunete ;Miguel Hernando Gutierrez ;David ÁlvarezThe integration of mobile robotic platforms with depth sensors could led to a major advance in human gait analysis. However, the lack of dedicated technologies designed specifically for corridor-based gait analysis limits the availability of comprehensive tools to accurately and efficiently capture and analyze gait data in this specific context. In this study, control algorithms for person following and lane keeping of a mobile robotic platform named Robogait were applied and validated experimentally. The validity of using an Azure Kinect sensor for gait analysis was also examined using gait data collected from 10 participants and comparing its accuracy in gait signals and gait parameters with respect to a Vicon photogrammetric system. Results in controller design demonstrated a path following error of only 0.0446 m was measured on average, with a maximum deviation of 0.1420 m. The person tracking presented slight oscillations, however it did not affect the performance of the system in the gait analysis. An RMSE error of 12.68 was obtained for knee flex./ext., 5.54 for hip flex./ext., and just 0.06 m for the inter-ankle distance. Regarding gait descriptors analyzed, the Azure Kinect system provides reliable gait event measurements, though some discrepancies exist compared to Vicon. This study validates the use of the Azure Kinect sensor in gait analysis with mobile platforms. This offers a low-cost solution in real environments such as hospital corridors, contrary to in-lab gait analysis where the influence of equipment and the controlled environment could alter the gait pattern. The robot setup errors were comparable to static treadmill systems and similar to those of Vicon systems, which highlights its potential in clinical and rehabilitation applications. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Non-Invasive Multi-Camera Gait Analysis System and its Application to Gender Classification(Institute of Electrical and Electronics Engineers (IEEE), 2020); ;Alberto BruneteMiguel HernandoObjective: Most studies have conducted human gait analysis using expensive and invasive photogrammetric systems. The objective of this study was to demonstrate that non-invasive and cost-effective systems based on depth cameras may be able to retrieve relevant features of human gait patterns. We aimed to prove this by solving the problem of gait classification by gender. Methods: 81 participants (40 female and 41 male) walked at a self-selected speed across a 4.8-meter walkway. Gait data was recorded using multiple depth sensors. Analysis in time domain included joint excursions by gait phases, range of movement (ROM), central tendency and dispersion measures, spatial variables, and center of mass (COM) position. The spectral analysis included principal frequency, magnitude, and phase shift during walking. Only features with significant differences by gender were used to train a support vector machine (SVM) classifier. Results: A total of 108 features presented significant differences by gender (p<; 0.05). On this basis, the accuracy of the chosen model was 96.7%. Trunk rotation, trunk sway, knee abduction/adduction, and pelvic obliquity were the most differentiated between the groups. The COM position shown a significant difference by gender (p=0.0065) with 51.7% and 51.0% for men and women respectively. Women proved to have significantly shorter normalized step width than men (p=0.0472). Conclusion: The proposed method was able to retrieve most of human gait features correctly, including differences in gait pattern by gender. Significance: Depth cameras represent a cost-effective system that could be used for a deeper biomechanical human gait analysis.Scopus© Citations 26 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Development and validation of a ROS-based mobile robotic platform for human gait analysis applicationsBackground: The integration of mobile robotic platforms in human gait analysis offers the potential to develop multiple medical applications and achieve new discoveries. The aim of this paper is to present a first design and validation of a ROS-based mobile robotic platform for human gait analysis. Methods: During the design stage, the model identification and the configuration of the control law were performed. The design of the control law required the integration of a lead compensator and a Filtered Smith Predictor (FSP). During the validation procedure, the accuracy of the system to retrieve kinematic gait data and the main descriptors of gait disorders was calculated with respect to the ground truth of a Vicon system. For this purpose, one hundred gait recordings were processed thanks to the collaboration of twenty participants. The participants walked in a one-way straight line gait. Results: Results showed high correlation and low error rates mainly in joint excursions from sagittal and transverse planes. Conclusion: This gait analysis system demonstrated several advantages compared with the current approaches. The use of a mobile robotic platform allowed gait analysis in long tracking ranges and without space limitations. Furthermore, the design of a suitable control law allowed a smooth tracking of the person. This led to optimal results when assessing joint excursions. Significance: This system represents a cost-effective and non-invasive alternative that could be used for human gait analysis applications.Scopus© Citations 19 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Robotics‐driven gait analysis: Assessing Azure Kinect's performance in in‐lab versus in‐corridor environments(Wiley, 2024-03-13); ;Alberto Brunete ;Miguel Hernando ;David ÁlvarezErnesto GambaoAbstract Gait analysis offers vital insights into human movement, aiding in the diagnosis, treatment, and rehabilitation of various conditions. Analyzing gait in corridors, rather than in lab, provides unique advantages for a more comprehensive understanding of human locomotion. However, limited dedicated technologies constrain gait data analysis in this context. In this study, a markerless gait analysis system using an Azure Kinect sensor mounted on a mobile robot is proposed and validated as a potential solution for gait analysis in corridors. Ten healthy participants (4 males and 6 females) underwent two tests. The first test (5 trials per participant) took place in the laboratory. Here, Azure Kinect performance was validated against a Vicon system, assessing eight gait signals and 22 gait parameters. The second test (2 trials per participant) was performed in the corridors over a 32‐m walking distance to compare this gait pattern with the one developed within the laboratory. The intrasession Intraclass Correlation Coefficient (ICC) reliability for in‐lab experiments was assessed by calculating the ICC between gait cycles captured in each session per participant. Notably, knee flexion/extension (ICC‐0.95), hip flexion/extension (ICC‐0.96), pelvis rotation (ICC‐0.88), and interankle distance (ICC‐0.98) demonstrated excellent reliability with high confidence. Similarly, hip adduction/abduction showed good reliability (ICC‐0.79), while trunk rotation exhibited moderate reliability (ICC‐0.72). In contrast, both trunk tilt (ICC‐0.24) and pelvis tilt (ICC‐0.41) consistently displayed lower reliability. This was observed for both the Vicon and the Azure systems, highlighting the intricate nature of capturing precise data for these specific signals in both systems. Validity outcomes indicated comparable error rates to literature standards ( knee flexion/extension, hip flexion/extension, and hip adduction/abduction), with 11 parameters having no significant differences from Vicon. Comparison of in‐lab and in‐corridor experiments show that individuals exhibit significantly longer stride time (1.10 s vs. 1.05 s), lower pelvis tilt ( vs. ), and lower minimum pelvis rotation ( vs. ) when walking in the laboratory. This study demonstrates promising outcomes in outdoor gait analysis with a robot‐mounted camera, revealing significant distinctions from controlled laboratory evaluations.Scopus© Citations 6 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, The Accuracy of the Microsoft Kinect V2 Sensor for Human Gait Analysis. A Different Approach for Comparison with the Ground Truth(MDPI AG, 2020-08-07); ;Alberto Brunete ;Miguel Hernando ;Javier RuedaEnrique Navarro CabelloSeveral studies have examined the accuracy of the Kinect V2 sensor during gait analysis. Usually the data retrieved by the Kinect V2 sensor are compared with the ground truth of certified systems using a Euclidean comparison. Due to the Kinect V2 sensor latency, the application of a uniform temporal alignment is not adequate to compare the signals. On that basis, the purpose of this study was to explore the abilities of the dynamic time warping (DTW) algorithm to compensate for sensor latency (3 samples or 90 ms) and develop a proper accuracy estimation. During the experimental stage, six iterations were performed using the a dual Kinect V2 system. The walking tests were developed at a self-selected speed. The sensor accuracy for Euclidean matching was consistent with that reported in previous studies. After latency compensation, the sensor accuracy demonstrated considerably lower error rates for all joints. This demonstrated that the accuracy was underestimated due to the use of inappropriate comparison techniques. On the contrary, DTW is a potential method that compensates for the sensor latency, and works sufficiently in comparison with certified systems.Scopus© Citations 37 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Instrumentation Techniques for Nuclear Pulse Shaping and Calibration in Geiger–Müller-Based Gamma Detectors(MDPI AG, 2026-05-14); ; ;Bastidas-Pazmiño, Jorge ;Pavón, ErikaChamorro, William - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Optimizing Electrical Systems Stability: A Novel Lyapunov Framework for Harmonic Reduction and Power Quality Enhancement(IEEE, 2024-08-05) ;Wilson Pavón ;Michael Chamorro ;Ismael Michala; Mohan KolheThis study investigates power quality improvement through a Lyapunov-based harmonic reduction strategy utilizing an Active Hybrid Power Filter (SHAPF). Central to this approach is the application of state feedback to maintain system stability. A practical case study examining the influence of a Nonlinear Load (NLL) on an IEEE 13-bus distribution system validates the proposed methodology. Implemented and scrutinized via Matlab/Simulink, this research encompasses the detailed modeling of the SHAPF, its control strategies, and the analysis of harmonic distortion data. Such an in-depth simulation facilitates a rigorous evaluation of the method in conditions mirroring real-world scenarios, shedding light on its efficacy and applicability. Harnessing the principles of Lyapunov theory alongside advanced control techniques, the objective is to markedly diminish harmonic distortions in power systems, thereby significantly improving power quality and Electrical Compatibility (EC). This contribution highlights a commitment to enhancing the reliability and quality of modern power system engineering through innovative solutions. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Multivariate System Identification of Differential Drive Robot: Comparison Between State-Space and LSTM-Based ModelsModeling mobile robots is crucial to odometry estimation, control design, and navigation. Classical state-space models (SSMs) have traditionally been used for system identification, while recent advances in deep learning, such as Long Short-Term Memory (LSTM) networks, capture complex nonlinear dependencies. However, few direct comparisons exist between these paradigms. This paper compares two multivariate modeling approaches for a differential drive robot: a classical SSM and an LSTM-based recurrent neural network. Both models predict the robot’s linear (v) and angular (ω) velocities using experimental data from a five-minute navigation sequence. Performance is evaluated in terms of prediction accuracy, odometry estimation, and computational efficiency, with ground-truth odometry obtained via a SLAM-based method in ROS2. Each model was tuned for fair comparison: order selection for the SSM and hyperparameter search for the LSTM. Results show that the best SSM is a second-order model, while the LSTM used seven layers, 30 neurons, and 20-sample sliding windows. The LSTM achieved a FIT of 93.10% for v and 90.95% for ω, with an odometry RMSE of 1.09 m and 0.23 rad, whereas the SSM outperformed it with FIT values of 94.70% and 91.71% and lower RMSE (0.85 m, 0.17 rad). The SSM was also more resource-efficient (0.00257 ms and 1.03 bytes per step) compared to the LSTM (0.0342 ms and 20.49 bytes). The results suggest that SSMs remain a strong option for accurate odometry with low computational demand while encouraging the exploration of hybrid models to improve robustness in complex environments. At the same time, LSTM models demonstrated flexibility through hyperparameter tuning, highlighting their potential for further accuracy improvements with refined configurations.Scopus© Citations 2
- «
- 1 (current)
- 2
- 3
- »
