GUFFANTI MARTÍNEZ, DIEGO ANDRES
Preferred name
GUFFANTI MARTÍNEZ, DIEGO ANDRES
Main Affiliation
GISER - Grupo de Investigación en Sistemas Embebidos y Robótica
Web Site
ORCID
0000-0002-1244-291X
Scopus Author ID
57200385407
23 results
Now showing 1 - 10 of 23
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Unmanned Aerial Vehicle Position Tracking Using Nonlinear Autoregressive Exogenous Networks Learned from Proportional-Derivative Model-Based Guidance(MDPI AG, 2025-07-24); ;Jorge Chavez ;Ama Baduba Asiedu-AsanteThe growing demand for agile and reliable Unmanned Aerial Vehicles (UAVs) has spurred the advancement of advanced control strategies capable of ensuring stability and precision under nonlinear and uncertain flight conditions. This work addresses the challenge of accurately tracking UAV position by proposing a neural-network-based approach designed to replicate the behavior of classical control systems. A complete nonlinear model of the quadcopter was derived and linearized around a hovering point to design a traditional proportional derivative (PD) controller, which served as a baseline for training a nonlinear autoregressive exogenous (NARX) artificial neural network. The NARX model, selected for its feedback structure and ability to capture temporal dynamics, was trained to emulate the control signals of the PD controller under varied reference trajectories, including step, sinusoidal, and triangular inputs. The trained networks demonstrated performance comparable to the PD controller, particularly in the vertical axis, where the NARX model achieved a minimal Mean Squared Error (MSE) of 7.78×10−5 and an R2 value of 0.9852. These results confirm that the NARX neural network, trained via supervised learning to emulate a PD controller, can replicate and even improve classical control strategies in nonlinear scenarios, thereby enhancing robustness against dynamic changes and modeling uncertainties. This research contributes a scalable approach for integrating neural models into UAV control systems, offering a promising path toward adaptive and autonomous flight control architectures that maintain stability and accuracy in complex environments.Scopus© Citations 1 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Human Gait Analysis Using Non-invasive Methods with a ROS-Based Mobile Robotic Platform(Springer International Publishing, 2020-11-10); ;Alberto BruneteMiguel Hernando GutierrezMobile robotic platforms for human gait analysis could open the gap to multiple medical applications and new discoveries. They could take several advantages over certified photogrammetric systems by making possible gait analysis without space limitations. In this document we present the design of a new ROS-based mobile robot platform for human gait analysis. All processes are ROS-based and Nuitrack SDK is used to develop the skeleton tracking application with a depth camera. During the procedure we described the design of the control law implemented for gait analysis. We developed a lead compensator by root locus method to increase the stability and speed response of the system. The error of measurement with respect to a certified photogrammetric system was considerably low during positioning task. Additional measurements were performed to verify the acquisition of gait parameters. These included spatio-temporal variables and range of movement (ROM) of knee and hip during joint excursions. Results showed that this mobile robotic platform represents a non-invasive alternative that could be improved for use in biomechanical human gait analysis.Scopus© Citations 2 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, RoboGait: sistema robótico no invasivo para el análisis de la marcha humana(Universitat Politecnica de Valencia, 2023-10-31) ;David Álvarez; ;Alberto Brunete ;Miguel HernandoErnesto GambaoActualmente, los sistemas utilizados en laboratorios para analizar la marcha se basan en técnicas marcadores o sensores colocados sobre el cuerpo del paciente, lo que resulta en un proceso que requiere un tiempo largo de preparación y calibración, así como la incomodidad que causa a los pacientes tener dispositivos colocados por el cuerpo. Además, el espacio en el que se pueden realizar pruebas resulta muy limitado. En respuesta a estas problemáticas, se ha desarrollado el sistema robótico RoboGait. Consiste en un robot móvil capaz de navegar autónomamente delante del paciente. El robot incluye una cámara RGBD en su parte superior para captar el cuerpo humano. Este sistema no requiere marcadores adheridos al cuerpo del paciente ya que utiliza la información proporcionada por la cámara RGBD para analizar la marcha. El objetivo de este estudio es demostrar la validez de RoboGait y su aplicabilidad en entornos clínicos. Para conseguirlo, se ha optado por mejorar la estimación de señales cinemáticas y espacio-temporales de la marcha procesando las medidas de la cámara con redes neuronales artificiales (RNA) entrenadas usando datos obtenidos de un sistema Vicon certificado. Posteriormente, se ha medido el rendimiento del sistema en la clasificación de patrones normales y patológicos, utilizando como referencia un sistema basado en sensores inerciales Xsens. De este modo, se ha probado el sistema robótico móvil en un rango amplio de la marcha, al tiempo que se ha comparado con un sistema comercial en las mismas condiciones experimentales. Los resultados obtenidos demuestran que RoboGait puede realizar el análisis de la marcha con suficiente precisión,mostrando un gran potencial para su análisis clínico y la identificación de patologías. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, A Comprehensive Review of Vision-Based Sensor Systems for Human Gait AnalysisAnalysis of the human gait represents a fundamental area of investigation within the broader domains of biomechanics, clinical research, and numerous other interdisciplinary fields. The progression of visual sensor technology and machine learning algorithms has enabled substantial developments in the creation of human gait analysis systems. This paper presents a comprehensive review of the advancements and recent findings in the field of vision-based human gait analysis systems over the past five years, with a special emphasis on the role of vision sensors, machine learning algorithms, and technological innovations. The relevant papers were subjected to analysis using the PRISMA method, and 72 articles that met the criteria for this research project were identified. A detailing of the most commonly used visual sensor systems, machine learning algorithms, human gait analysis parameters, optimal camera placement, and gait parameter extraction methods is presented in the analysis. The findings of this research indicate that non-invasive depth cameras are gaining increasing popularity within this field. Furthermore, depth learning algorithms, such as convolutional neural networks (CNNs) and long short-term memory (LSTM) networks, are being employed with increasing frequency. This review seeks to establish the foundations for future innovations that will facilitate the development of more effective, versatile, and user-friendly gait analysis tools, with the potential to significantly enhance human mobility, health, and overall quality of life. This work was supported by [GOBIERNO DE ESPANA/PID2023-150967OB-I00].Scopus© Citations 49 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Organic zinc sources in broiler production at high altitude under on-top supplementation or total or partial replacement: 1. Effects on performance and zinc excretionFeeding broilers with organic chemical sources of Zn has recently been recommended to improve performance, immune system, carcass yield, and reduce environmental contamination. However, its use under proposed supplementation strategies (i.e., total replacement, partial replacement, on-top) needs further investigation. This study assessed the effect of total replacement, partial replacement, and on-top supplementation strategies to feed organic Zn sources and the effect of two organic chemical forms on performance and Zn excretion in broilers at high altitudes. Twenty-two male Cobb 500-day-old chicks were placed in each of 54 floor pens and raised for up to 42 days under a three-phase feeding program and following the Ecuadorian highland production system. Pens were assigned to one of nine experimental treatments consisting of a basal diet supplemented with 0, 33, and 100 ppm of Zn from ZnSO4 and added or not 40 ppm Zn from Zn proteinate or Zn amino acid complex. A Completely Randomized Block Design was considered, being the block the replication. The Zn concentration of the basal diet was determined. Feed intake, BW, BW gain, feed conversion ratio, and European Production Efficiency Factor were assessed at 21 and 42 days of age, and the Zn excretion was estimated accordingly. Each supplementation strategy was compared with the standard practice (100 ppm Zn as ZnSO4) using contrasts and mixed models, and the interaction with the chemical form was assessed considering the P-values of the ANOVA and the multiple comparisons between the corresponding treatments. The effects of the organic Zn forms and their interactions with the dietary Zn level were assessed considering the responses were linear functions of the organic Zn source, the feed intake, the Zn intake, the Zn supplementation level, and the block, as corresponding. None of the strategies to supplement a Zn organic source, or the organic sources themselves, showed overall detectable effects on performance. However, interactions were observed between the supplementation strategy and the organic Zn source and between the organic source and the dietary Zn levels or the Zn intake. Under the on-top supplementation strategy, the Zn organic sources showed different feed conversion ratios at 21 days. In addition, totally or partially replacing the ZnSO4 with a Zn organic form reduced the Zn excretion. In conclusion, although no overall effect of the supplementation strategies was detected, the assessed organic Zn forms showed different effects on the feed conversion ratio at 21 days.Scopus© Citations 4 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Robotics‐driven gait analysis: Assessing Azure Kinect's performance in in‐lab versus in‐corridor environments(Wiley, 2024-03-13); ;Alberto Brunete ;Miguel Hernando ;David ÁlvarezErnesto GambaoAbstract Gait analysis offers vital insights into human movement, aiding in the diagnosis, treatment, and rehabilitation of various conditions. Analyzing gait in corridors, rather than in lab, provides unique advantages for a more comprehensive understanding of human locomotion. However, limited dedicated technologies constrain gait data analysis in this context. In this study, a markerless gait analysis system using an Azure Kinect sensor mounted on a mobile robot is proposed and validated as a potential solution for gait analysis in corridors. Ten healthy participants (4 males and 6 females) underwent two tests. The first test (5 trials per participant) took place in the laboratory. Here, Azure Kinect performance was validated against a Vicon system, assessing eight gait signals and 22 gait parameters. The second test (2 trials per participant) was performed in the corridors over a 32‐m walking distance to compare this gait pattern with the one developed within the laboratory. The intrasession Intraclass Correlation Coefficient (ICC) reliability for in‐lab experiments was assessed by calculating the ICC between gait cycles captured in each session per participant. Notably, knee flexion/extension (ICC‐0.95), hip flexion/extension (ICC‐0.96), pelvis rotation (ICC‐0.88), and interankle distance (ICC‐0.98) demonstrated excellent reliability with high confidence. Similarly, hip adduction/abduction showed good reliability (ICC‐0.79), while trunk rotation exhibited moderate reliability (ICC‐0.72). In contrast, both trunk tilt (ICC‐0.24) and pelvis tilt (ICC‐0.41) consistently displayed lower reliability. This was observed for both the Vicon and the Azure systems, highlighting the intricate nature of capturing precise data for these specific signals in both systems. Validity outcomes indicated comparable error rates to literature standards ( knee flexion/extension, hip flexion/extension, and hip adduction/abduction), with 11 parameters having no significant differences from Vicon. Comparison of in‐lab and in‐corridor experiments show that individuals exhibit significantly longer stride time (1.10 s vs. 1.05 s), lower pelvis tilt ( vs. ), and lower minimum pelvis rotation ( vs. ) when walking in the laboratory. This study demonstrates promising outcomes in outdoor gait analysis with a robot‐mounted camera, revealing significant distinctions from controlled laboratory evaluations.Scopus© Citations 6 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, ROBOGait: A Mobile Robotic Platform for Human Gait Analysis in Clinical Environments(MDPI AG, 2021-10-13); ;Alberto Brunete ;Miguel Hernando ;Javier RuedaEnrique NavarroMobile robotic platforms have made inroads in the rehabilitation area as gait assistance devices. They have rarely been used for human gait monitoring and analysis. The integration of mobile robots in this field offers the potential to develop multiple medical applications and achieve new discoveries. This study proposes the use of a mobile robotic platform based on depth cameras to perform the analysis of human gait in practical scenarios. The aim is to prove the validity of this robot and its applicability in clinical settings. The mechanical and software design of the system is presented, as well as the design of the controllers of the lane-keeping, person-following, and servoing systems. The accuracy of the system for the evaluation of joint kinematics and the main gait descriptors was validated by comparison with a Vicon-certified system. Some tests were performed in practical scenarios, where the effectiveness of the lane-keeping algorithm was evaluated. Clinical tests with patients with multiple sclerosis gave an initial impression of the applicability of the instrument in patients with abnormal walking patterns. The results demonstrate that the system can perform gait analysis with high accuracy. In the curved sections of the paths, the knee joint is affected by occlusion and the deviation of the person in the camera reference system. This issue was greatly improved by adjusting the servoing system and the following distance. The control strategy of this robot was specifically designed for the analysis of human gait from the frontal part of the participant, which allows one to capture the gait properly and represents one of the major contributions of this study in clinical practice.Scopus© Citations 20 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Technological Advancements in Human Navigation for the Visually Impaired: A Systematic Review(MDPI AG, 2025-04-01) ;Edgar Casanova; Visually impaired people face significant obstacles when navigating complex environments. However, recent technological advances have greatly improved the functionality of navigation systems tailored to their needs. The objective of this research is to evaluate the effectiveness and functionality these navigation systems through a comparative analysis of recent technologies. For this purpose, the PRISMA 2020 methodology was used to perform a systematic literature review. After identification and screening, 58 articles published between 2019 and 2024 were selected from three academic databases: Dimensions (26 articles), Web of Science (18 articles), and Scopus (14 articles). Bibliometric analysis demonstrated a growing interest of the research community in the topic, with an average of 4.552 citations per published article. Even with the technological advances that have occurred in recent times, there is still a significant gap in the support systems for people with blindness due to the lack of digital accessibility and the scarcity of adapted support systems. This situation limits the autonomy and inclusion of people with blindness, so the need to continue developing technological and social solutions to ensure equal opportunities and full participation in society is evident. This study emphasizes the great advances with the integration of sensors such as high-precision GPS, ultrasonic sensors, Bluetooth, and various assistance apps for object recognition, obstacle detection, and trajectory generation, as well as haptic systems, which provide tactile information through wearables or actuators and improve spatial awareness. Current navigation algorithms were also identified in the review with methods including obstacle detection, path planning, and trajectory prediction, applied to technologies such as ultrasonic sensors, RGB-D cameras, and LiDAR for indoor navigation, as well as stereo cameras and GPS for outdoor navigation. It was also found that AI systems employ deep learning and neural networks to optimize both navigation accuracy and energy efficiency. Finally, analysis revealed that 79% of the 58 reviewed articles included experimental validation, 87% of which were on haptic systems and 40% on smartphones. These results underscore the importance of experimentation in the development of technologies for the mobility of people with visual impairment.Scopus© Citations 32 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Supervised learning for improving the accuracy of robot-mounted 3D camera applied to human gait analysis(Elsevier BV, 2024-02); ;Alberto Brunete ;Miguel Hernando ;David ÁlvarezJavier RuedaBackground and Objective: the use of 3D cameras for gait analysis has been highly questioned due to the low accuracy they have demonstrated in the past. The objective of the study presented in this paper is to improve the accuracy of the estimations made by robot-mounted 3D cameras in human gait analysis by applying a supervised learning stage. Methods: the 3D camera was mounted in a mobile robot to obtain a longer walking distance. This study shows an improvement in detection of kinematic gait signals and gait descriptors by post-processing the raw estimations of the camera using artificial neural networks trained with the data obtained from a certified Vicon system. To achieve this, 37 healthy participants were recruited and data of 207 gait sequences were collected using an Orbbec Astra 3D camera. There are two basic possible approaches for training and both have been studied in order to see which one achieves a better result. The artificial neural network can be trained either to obtain more accurate kinematic gait signals or to improve the gait descriptors obtained after initial processing. The former seeks to improve the waveforms of kinematic gait signals by reducing the error and increasing the correlation with respect to the Vicon system. The second is a more direct approach, focusing on training the artificial neural networks using gait descriptors directly. Results: the accuracy of the 3D camera to objectify human gait was measured before and after training. In both training approaches, a considerable improvement was observed. Kinematic gait signals showed lower errors and higher correlations with respect to the ground truth. The accuracy of the system to detect gait descriptors also showed a substantial improvement, mostly for kinematic descriptors rather than spatio-temporal. When comparing both training approaches, it was not possible to define which was the absolute best. Conclusions: supervised learning improves the accuracy of 3D cameras but the selection of the training approach will depend on the purpose of the study to be conducted. This study reveals the great potential of 3D cameras and encourages the research community to continue exploring their use in gait analysis.Scopus© Citations 6 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Performance of a Mobile 3D Camera to Evaluate Simulated Pathological Gait in Practical Scenarios(MDPI AG, 2023-08-04); ;Daniel Lemus ;Heike Vallery ;Alberto BruneteMiguel HernandoThree-dimensional (3D) cameras used for gait assessment obviate the need for bodily markers or sensors, making them particularly interesting for clinical applications. Due to their limited field of view, their application has predominantly focused on evaluating gait patterns within short walking distances. However, assessment of gait consistency requires testing over a longer walking distance. The aim of this study is to validate the accuracy for gait assessment of a previously developed method that determines walking spatiotemporal parameters and kinematics measured with a 3D camera mounted on a mobile robot base (ROBOGait). Walking parameters measured with this system were compared with measurements with Xsens IMUs. The experiments were performed on a non-linear corridor of approximately 50 m, resembling the environment of a conventional rehabilitation facility. Eleven individuals exhibiting normal motor function were recruited to walk and to simulate gait patterns representative of common neurological conditions: Cerebral Palsy, Multiple Sclerosis, and Cerebellar Ataxia. Generalized estimating equations were used to determine statistical differences between the measurement systems and between walking conditions. When comparing walking parameters between paired measures of the systems, significant differences were found for eight out of 18 descriptors: range of motion (ROM) of trunk and pelvis tilt, maximum knee flexion in loading response, knee position at toe-off, stride length, step time, cadence; and stance duration. When analyzing how ROBOGait can distinguish simulated pathological gait from physiological gait, a mean accuracy of 70.4%, a sensitivity of 49.3%, and a specificity of 74.4% were found when compared with the Xsens system. The most important gait abnormalities related to the clinical conditions were successfully detected by ROBOGait. The descriptors that best distinguished simulated pathological walking from normal walking in both systems were step width and stride length. This study underscores the promising potential of 3D cameras and encourages exploring their use in clinical gait analysis.</jats:p>Scopus© Citations 2
- «
- 1 (current)
- 2
- 3
- »
