  4. Innovation in the percutaneous management of benign hepaticojejunostomy stricture with multiple lithiasis using SpyGlass Discover and biodegradable stent: a case report
Details

Innovation in the percutaneous management of benign hepaticojejunostomy stricture with multiple lithiasis using SpyGlass Discover and biodegradable stent: a case report

Journal
Journal of Surgical Case Reports
ISSN
2042-8812
Date Issued
2025-11-01
Author(s)
Edison Santiago Borja Villacrés
Jefferson Andrés Carvajal Torres
Santiago Andrés Muñoz-Palomeque
DOI
10.1093/jscr/rjaf878
URL
https://cris.ute.edu.ec/handle/123456789/1826
Abstract
We report the case of a 51-year-old female with a history of iatrogenic bile duct injury treated with hepaticojejunostomy in 2013 and reconstruction in 2016.

She developed recurrent anastomotic stricture and intrahepatic lithiasis, with multiple failed surgical and endoscopic attempts, for that reason a two-stage percutaneous approach was performed: initial transhepatic cholangiography, crossing the stricture area and placing an internal-external biliary catheter; followed by cholangioscopy through a mature tract using the Spyglass Discover system, electrohydraulic lithotripsy of intrahepatic stones, endoluminal balloon plasty, and placement of biodegradable stent fifteen days later.

The patient achieved complete clearance of intrahepatic stones, stricture resolution, and normalization of liver biochemistry without early recurrence.

This case highlights the feasibility and efficacy of a minimally invasive percutaneous strategy combining cholangioscopy, lithotripsy, and biodegradable stenting for complex benign hepaticojejunostomy strictures, even in nondilated bile ducts, avoiding the morbidity of open surgery.
Subjects

hepaticojejunostomy

bile duct stricture

percutaneous cholangi...

lithotripsy

biodegradable stent

spyglass