Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. CRIS
  3. Publication
  4. Analysis of Polycyclic Aromatic Hydrocarbons Using Magnetic Three-Dimensional Graphene Solid-Phase Extraction Coupled with Gas Chromatography–Mass Spectrometry
Details

Analysis of Polycyclic Aromatic Hydrocarbons Using Magnetic Three-Dimensional Graphene Solid-Phase Extraction Coupled with Gas Chromatography–Mass Spectrometry

Journal
Separations
ISSN
2297-8739
Date Issued
2023-11-10
Author(s)
Hassan Sereshti
Mahsa Karimi
Sajad Karami
Shokouh Mahpishanian
Mehdi Esmaeili Bidhendi
Shahabaldin Rezania
Amin Mojiri
Hesam Kamyab
Facultad de Arquitectura y Urbanismo  
Hamid Rashidi Nodeh
DOI
10.3390/separations10110564
URL
https://cris.ute.edu.ec/handle/123456789/322
Abstract
<jats:p>In this study, a composite material consisting of three-dimensional graphene aerogel and iron oxide nanoparticles (3DG/Fe3O4) was created and utilized for the purpose of magnetic solid-phase extraction (MSPE) of thirteen polycyclic aromatic hydrocarbon (PAH) compounds via gas chromatography–mass spectrometry/selected ion monitoring (GC-MS/SIM) analysis. The synthesized adsorbent underwent a range of characterization techniques, including scanning electron microscopy, vibrating sample magnetometry, Raman spectroscopy, X-ray diffraction, Brunauer–Emmett–Teller, Fourier transform-infrared spectroscopy, and Barrett–Joyner–Halenda techniques, to examine its properties and morphology. The synthesized adsorbent integrates the benefits of superior adsorption capacity from modified graphene oxide (GO) with the magnetic separability of magnetite microparticles, resulting in a high adsorption capacity with easy separation from sample solutions. The efficiency of the proposed method was optimized and modeled using a central composite design (CCD), which considered the primary factors influencing it. The optimal conditions were obtained as the adsorbent dosage of 10 mg, the extraction time of 4 min, and the salt concentration of 3% w/v. The limit of detection for the target PAHs was established to range from 0.016 to 0.2 ng mL−1 in optimal conditions, exhibiting a signal-to-noise ratio of 3. The linear dynamic range spanned from 5 to 100 ng mL−1, with determination coefficients (R2) ranging from 0.9913 to 0.9997. The intra- and inter-day precisions were calculated as relative standard deviations (RSDs) equal to 3.9% and 4.7%, respectively. The proposed method was successfully applied to the determination of PAHs in water samples (tap, river, and rainwater), and recoveries in the range of 71–110% (RSDs < 5.2%, n = 3) were obtained.</jats:p>

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback

Hosting & Support by

Built with DSpace-CRIS software - Extension maintained and optimized by 4science

Repository logo COAR Notify